
Add to Cart
CR17335SE 1800mAh LiMnO2 Battery High Power Customized UN CE UL Certification
Nominal Capacity | 1800mAh |
Battery discharged at continuous current 1mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃ | |
Nominal Voltage | 3.0 V |
Maximum Continuous Current | 10mA |
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃ | |
Maximum Pulse Discharge Current | 100mA |
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃ | |
Storage Condition | Temperature ≤ 30℃ Humidity ≤ 75%RH |
Operating Temperature | -40℃ to +85℃ |
Battery Dimension | See drawing on pag |
Max Weight | 22.0g |
Self-discharge Rate | 2% |
Max self-discharged rate at ambient temperature 23±2℃ | |
Shelf Life | 10 years |
Ambient temperature 23±2℃ |
1. Battery Characteristic
Single cell rated voltage 3.0V
We provide the specific energy density up to 245Wh/kg
Battery working temperature range from -40℃ to +85℃
The battery self-discharge less than 2% per year at room temperature
High capacity, stable performance, without passivation
Hermetic welding sealing to reduce the leakage for extending the shelf life to more than 10 years
High safety performance, reliable and environmental friendly
2. Main Applications
RFID products, road toll transponder, IC cards, etc.
Smoke detectors, security alarms, seismometers, locking system, monitoring system, etc.
Wireless telecommunication devices
3. Manufacturing Advantages
4. Company Advantages
5. FAQS of General Safety Instructions
The battery should be kept as dryly as possible when they are in storage.
We need to stop using the battery when the abnormal heat release or leakage occurs.
We need to stop using the battery when the abnormal heat release or leakage occurs.
The manual should be read before the battery is used.
If + and - polarity of battery is connected directly, it causes a short circuit and this may lead toxic gas and materials leakage or a big rupture.
They are going to be hot in very short time and it will lead the leakage of gas and toxic materials which may cause a big rupture.
When changing batteries be aware that batteries of different electrochemical system, grades, or brands should be not mixed. If different batteries are used or in case of using old and new batteries together this can discharge batteries due to different voltage or capacity. This can cause toxic material or gas leakage and/or violent rupture.