Add to Cart
1500mAh CR-P2 Lithium Battery Pack , Li Battery Pack Lithium Manganese Dioxide Cell
Nominal Capacity | 1500mAh |
Battery discharged at continuous current 1mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃ | |
Nominal Voltage | 6.0 V |
Maximum Continuous Current | 1500mA |
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃ | |
Maximum Pulse Discharge Current | 3000mA |
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃ | |
Storage Condition | Temperature ≤ 30℃ Humidity ≤ 75%RH |
Operating Temperature | -40℃ to +85℃ |
Battery Dimension | See drawing on pag |
Max Weight | 45.0g |
Self-discharge Rate | 2% |
Max self-discharged rate at ambient temperature 23±2℃ | |
Shelf Life | 10 years |
Ambient temperature 23±2℃ |
1. Battery Characteristic
We offer the rated voltage of 6.0V
We offer the specific energy density of 200Wh/kg
The battery can be in work between -40℃ ~ +85℃
Under the condition of normal temperature, the battery self -discharge rate of no more than 2% per year
High capacity, stable performance, stable discharge voltage, and no voltage passivation after long time storage
Hermetic welding sealing to reduce the leakage for extending the shelf life to more than 10 years
High safety performance, reliable and environmental friendly.
2. Main Applications
RFID products, road toll transponder, IC cards, etc.
Smoke detectors, security alarms, seismometers, locking system, monitoring system, etc.
Wireless telecommunication devices
3. Manufacturing Advantages
4. Company Advantages
5. FAQS of General Safety Instructions
Storage environment should be as dry as possible.
We need to stop using the battery when the abnormal heat release or leakage occurs.
You need to follow the signs + and - on the batteries and make sure not to reverse. If batteries are wrongly used, they will be hot very fast and can lead the gas and other toxic materials leakage.
They will be hot very fast and can lead the gas and other toxic materials leakage if they are closed to fire.
When changing batteries be aware that batteries of different electrochemical system, grades, or brands should be not mixed. If different batteries are used or in case of using old and new batteries together this can discharge batteries due to different voltage or capacity. This can cause toxic material or gas leakage and/or violent rupture.
The batteries can not be soldered directly. If they are directly soldered, it will cause short circuit and a gas and toxic material leakage or big rupture.
The water explosion will be caused if you throw the batteries into the water.