High Energy Density Lithium Thionyl Chloride Cell ER14505 Lithium Battery
Nominal Capacity | 2500mAh |
Battery discharged at continuous current 1.35mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃ | |
Nominal Voltage | 3.6 V |
Maximum Continuous Current | 100mA |
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃ | |
Maximum Pulse Discharge Current | 200mA |
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃ | |
Storage Condition | Temperature ≤ 30℃ Humidity ≤ 75%RH |
Operating Temperature | -55℃ to +85℃ |
Battery Dimension | See drawing on pag |
Max Weight | 20.0g |
Self-discharge Rate | 2% |
Max self-discharged rate at ambient temperature 23±2℃ | |
Shelf Life | 10 years |
Ambient temperature 23±2℃ |
1. Battery Characteristic
We offer the rated voltage of 3.6V, the working voltage varies with the load, generally between 3.3V ~ 3.6V
We offer the specific energy density of 450Wh/kg
We provide a wide operating temperature range, from -55℃ to +85℃
Stable operating voltage, more than 90% of the capacity could be output with a fixed voltage
Under the condition of normal temperature, the battery self -discharge rate of no more than 2% per year
Battery sealing using the fully sealed structure to reduce the leakage of the battery, make the battery can be stored at room temperature for more than 10 years
2. Main Applications
Smoke detectors, security alarms, seismometers, locking system, monitoring system, etc.
Life jacket, signal light, buoy, etc.
Cardiac pacemaker, respirator, oxygenator, inspection devices, monitoring devices, infusion pump, etc.
3. Manufacturing Advantages
4. Company Advantages
5. FAQS of General Safety Instructions
The battery should be kept as dryly as possible when they are in storage.
When the abnormal heat release or leakage occurs, the battery is not able to be continued to use.
You need to keep battery out of the children. Please call to a physician immediately if it is swallowed by children.
They will be hot very fast and can lead the gas and other toxic materials leakage if they are closed to fire.
The batteries are able to be deformed or drilled into or damaged because the toxic materials or gas leakage may lead a big rupture.
The batteries of different electrochemical system, grades, or brands can’t be mixed because it would lead toxic material or gas leakage and/or a big rupture.
The batteries are not able to put or thrown into the water because it would cause explosion.