HCB Battery Co., Ltd
City:wuhan
Province/State:hubei
Country/Region:china
Contact Now

Cylindrical Li-SOCl2 Battery , ER26500 Lithium Battery Resistance Corrosion

Ask Latest Price
Video Channel
Brand Name :HCB
Model Number :ER26500
Certification :UN/CE/UL
Place of Origin :Hubei Wuhan
Price :negotiable
MOQ :1K pcs
Payment Terms :T/T, L/C
Supply Ability :two million unit per month
Delivery Time :35 work days
Packaging Details :Special design for Air/Sea/Courier transportation
Cellpacking :304 stainless steel
Classification :Bobbin
Max Size(mm) :Φ26.2×50.0
Nominal Voltage(V) :3.6
Nominal Capacity(mAh) :8500
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Cylindrical Li-SOCl2 Battery , ER26500 Lithium Battery Resistance Corrosion

Nominal Capacity 8500mAh
Battery discharged at continuous current 3.3mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage 3.6 V
Maximum Continuous Current 200mA
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃
Maximum Pulse Discharge Current 400mA
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature -55℃ to +85℃
Battery Dimension See drawing on pag
Max Weight 53.0g
Self-discharge Rate 2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life 10 years
Ambient temperature 23±2℃

1. Battery Characteristic

  • High Voltage

The nominal voltage of single cell up to 3.6V, the operating voltage varies with the load, normally between 3.3V and 3.6V

  • High Energy Density

We offer the specific energy density of 577Wh/kg

  • Wide Operating Temperature Range

The battery with a strong adaptability to temperature can be in work between -55℃ ~ +85℃

  • Stable Operating Voltage

Stable operating voltage, more than 90% of the capacity could be output with a fixed voltage

  • Long Shelf Life

The battery self-discharge less than 2% per year at room temperature

Hermetic welding sealing to reduce the leakage for extending the shelf life to more than 10 years

2. Main Applications

  • Marine & signaling

Life jacket, signal light, buoy, etc.

  • Oil & gas

Well pressure meters in high temperature, float meter, logging while drilling (LWD), measure while drilling (MWD), etc.

  • Tracking

RFID products, road toll transponder, IC cards, etc.

3. Manufacturing Advantages

  • It is ok to use advance automatic technology in HCB;
  • Excellent control of passivation;
  • There are variety of solutions such as high power, high capacity or high temperature etc;
  • We can provide multiple cascade and parallel connection ways and combining suggestions with our customers if they need;
  • There are multiple safety designs for our products.
  • Since 1995, we have started to produce the Li-SOCl2 batteries and we have much experience in it;

4. Company Advantages

  • HCB quality management meets the standard GB/T19001-2008/ISO9001:2008;
  • HCB Environment Management System meets the standard GB/T24001-2004/ISO14001:2004;
  • Drop test package can be provided to your ordered battery if you need;
  • HCB can provide the report for safe transport of goods to the customers;
  • CE Standard is workable for HCB Battery;
  • HCB Battery has passed the Rosh standard;
  • UL Standard is workable for HCB Battery;

5. FAQS of General Safety Instructions

  • What kind of case do we need to stop using the battery?

The battery should be stopped to using when the abnormal heat release or leakage occurs.

  • If you have children at home, what should you pay attention when we use our battery?

The battery should be kept out of the children firstly. If swallowed by children, please contact a physician at once.

  • If the batteries are closed to the fire, what may happen?

The batteries may be incinerated or mutilated if they are closed to the fire and it leads a possible burst or they may release the toxic materials.

  • What will happen if the batteries are short circuit?

The batteries can’t be short circuit. If positive and negative polarity of a battery is directly connected, this may cause a short circuit and this may lead to toxic materials or gas leakage and/or violent rupture.

  • If the batteries are soldered directly, what will happen?

The batteries can not be soldered directly. If they are directly soldered, it will cause short circuit and a gas and toxic material leakage or big rupture.

  • Is it ok to put the batteries into the water?

The water explosion will be caused if you throw the batteries into the water.

  • How to do the batteries disposal?

During the batteries disposal, you need to follow the local and state regulations.