HCB Battery Co., Ltd

We Power Your Technology

Manufacturer from China
Active Member
9 Years
Home / Products / Li-SOCl2 Battery /

Li-SOCl2 Battery Primary Cell ER17450M Storing Temperature ≤ 30℃ forNon-rechargeable NB IOT LORA GSM

Contact Now
HCB Battery Co., Ltd
City:wuhan
Province/State:hubei
Country/Region:china
Contact Now

Li-SOCl2 Battery Primary Cell ER17450M Storing Temperature ≤ 30℃ forNon-rechargeable NB IOT LORA GSM

Ask Latest Price
Video Channel
Brand Name :HCB
Model Number :ER17450M
Certification :UN/CE/UL
Place of Origin :China
MOQ :1K pcs
Price :negotiable
Payment Terms :T/T, L/C, D/A, L/C, D/P, MoneyGram, Western Union
Supply Ability :two million unit per month
Delivery Time :5 working days
Packaging Details :Special design for Air/Sea/Courier transportation
Peak pulsing current :960mA
Working Temperature :From -55℃ to +85℃
Ambient Humidity in Storage :≤ 75%RH
Automatic discharge rate :2%
Time of Storage :10 years
Storing temperature :≤30℃
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Industrial Li-SOCl2 Battery Primary Cell ER17450M Storing Temperature ≤ 30℃

Nominal Capacity 2550mAh
Battery discharged at continuous current 4.8mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage 3.6 V
Maximum Continuous Current 480mA
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃
Maximum Pulse Discharge Current 960mA
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature -55℃ to +85℃
Battery Dimension See drawing on pag
Max Weight 23.0g
Self-discharge Rate 2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life 10 years
Ambient temperature 23±2℃

1. Battery Characteristic

  • High Voltage

The nominal voltage of single cell up to 3.6V, the operating voltage varies with the load, normally between 3.3V and 3.6V

  • High Energy Density

The specific energy density of each battery is 399Wh/kg

  • Wide Operating Temperature Range

The battery with a strong adaptability to temperature can be in work between -55℃ ~ +85℃

  • Stable Operating Voltage

Stable operating voltage, more than 90% of the capacity could be output with a fixed voltage

  • Long Shelf Life

The battery self-discharge less than 2% per year at room temperature

Hermetic welding sealing to reduce the leakage for extending the shelf life to more than 10 years

2. Main Applications

  • Electrical equipment

Wireless electric power tools, computer RAM & COMS, UPS, CNC machine tools, (TPMS), camera, video camera, timer, calculator, electric toys, lighting equipment, etc.

  • Security & alarms

Smoke detectors, security alarms, seismometers, locking system, monitoring system, etc.

  • Tracking

RFID products, road toll transponder, IC cards, etc.

3. Manufacturing Advantages

  • The technology in HCB is advanced and automatic;
  • There is excellent control of passivation in HCB;
  • There are variety of solutions such as high power, high capacity or low temperature etc;
  • We can provide multiple cascade and parallel connection ways and combining suggestions with our customers if they need;
  • The safety designs are multiple;
  • Professional technical team with more than 20 years experiences.

4. Company Advantages

  • Quality management system of HCB is conformity with GB/T19001-2008/ISO9001:2008 standard;
  • The Environment Management System in HCB is accord with GB/T24001-2004/ISO14001:2004;
  • The drop test is workable of HCB battery;
  • Report for safe transport of goods is workable for us if it is required;
  • The CE certificate can be given to you if required;
  • The Rosh certificate can be given to you if required;
  • The UL certificate can be given to you if required;

5. FAQS of General Safety Instructions

  • How about the storage environment of the battery?

The battery should be kept as dryly as possible when they are in storage.

  • What kind of case do we need to stop using the battery?

We need to stop using the battery when the abnormal heat release or leakage occurs.

  • What is the first step when you would like to use our battery?

The manual should be read before the battery is used.

  • What is the effect of the signs + and - on the battery?

You need to follow the signs + and - on the batteries and make sure not to reverse. If batteries are wrongly used, they will be hot very fast and can lead the gas and other toxic materials leakage.

  • What can't you do to the batteries?

The batteries are able to be deformed or drilled into or damaged because the toxic materials or gas leakage may lead a big rupture.

  • Can the batteries be mixed to use on different electrochemical system, grades or brands?

When changing batteries be aware that batteries of different electrochemical system, grades, or brands should be not mixed. If different batteries are used or in case of using old and new batteries together this can discharge batteries due to different voltage or capacity. This can cause toxic material or gas leakage and/or violent rupture.

  • What will happen if the batteries are thrown into the water?

The batteries are not able to be thrown into the water. This can cause the water explosion.

Li-SOCl2 Battery Primary Cell ER17450M Storing Temperature ≤ 30℃ forNon-rechargeable NB IOT LORA GSM

Inquiry Cart 0